HAWK I.R.

INFRARED EVOLVED


English
Francias
Deutsch

Product Demonstration

 

Specification

 

Safety Performance
ATEX Marking II 2 G
IEC Marking EEx py ib [ib] IIC T4/T2*
Safety Standards EN 60079-0:2006
  EN60079-2:2004
  EN 50014:1997 (A1 and A2)
  EN 50020:2002
EC-Type Examination Certificate # DNV-2006-OSL-ATEX-0529X
Certifying Body Det Norske Veritas (DNV)
Protection Systems Dupl-Ex Dual
Redundant Safety Trips
Safety Systems
Electrical Protection Intrinsically Safe (I.S.)
battery cells
Pressure Protection Nitrogen purged,
Dupl-Ex dual redundant
pressure trips.
Pressure Indication Primary and secondary
pressure indication
via docking station
Oxygen Depletion Automatic flush and N2
recharge via docking
station.
Seal Check Automatic pressurise
and hold routine via
docking station.
Environmental Performance
Ingress Protection (IP) IP67 (Immersion Proof)
Impact 1kg Steel Ball from 2m
Drop 80J
Operating Temperature Range -20°C to +40°C
Construction
Casing Aluminium
Shock absorption Silicone
Power Source
Electrical Dupl-Ex protection
Li-Ion, rechargeable,
Battery Runtime Upto three hours
External Power 240VAC 50Hz/12VDC
via docking station
(110V 60Hz available
upon request)
Power Saving User selectable autoshutdown/
sleep mode
Imaging Performance
Screen Armoured LCD display
Detector type LW Focal Plane Array
(FPA), uncooled
microbolometer
Thermal sensitivity (NETD) 0.1°C@30°C
Resolution 160 x 120 pixels
Spectral range 8~14μm
Field of view/min focus distance 18°x13°/0.3m
Spatial resolution 1.9 mrad
Focus Manual (oversize)
Frame rate 50Hz
Image Storage & Retrieval
Type Built in flash memory,
upto 100 image
on-board storage.
Retrieval Protected USB
download via docking
Station
Interfaces
USB Thermal image &
measurement data
Ex|CAM System Includes
• Ex|CAM IR Camera with wall mounted automatic
docking station.
• Power Supply
• Integral Intrinsically Safe (I.S) battery pack
• Report Software
• Operation & Maintenance Manual
• Cables
Optional Extras
Hands-free shoulder harness


*Ex|CAM Professional Series = T4
Ex|CAM Standard Series = T2